![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2301713.1 : T10000D - Lost Communication on the Data Path if Direct Attached to a VSM5
In this Document
Applies to:StorageTek T10000D Tape Drive - Version All Versions and laterSun StorageTek VSM5 System - Version All Versions and later Information in this document applies to any platform. SymptomsUnable to communicate on the data path if direct attached to a VSM5. ChangesPossible code upgrade to 4.12.106 brings out the problem. CauseTiming issue in the drive code can caused the data path communication to fail if the drive is direct attached to VSM5 and set for auto-negotiate. Switch attached drives do not have this issue. SolutionThe solution is to hard set the drive for 4 Gb transfer rate using VOP. Attachments This solution has no attachment |
||||||||||||||||||
|