Solution  2301713.1 :   T10000D - Lost Communication on the Data Path if Direct Attached to a VSM5  


Related Items
  • Sun StorageTek VSM5 System
  •  
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Sun StorageTek VSM5 System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 Unable to communicate on the data path if direct attached to a VSM5.

Changes

 Possible code upgrade to 4.12.106 brings out the problem.

Cause

 Timing issue in the drive code can caused the data path communication to fail if the drive is direct attached to VSM5 and set for auto-negotiate. Switch attached drives do not have this issue.

Solution

The solution is to hard set the drive for 4 Gb transfer rate using VOP. 