Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2300826.1
Update Date:2017-09-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  2300826.1 :   T10000C - FSC_2B31 SNO With Code Level 3.62.112 and 3.63.101 - Other T10000 Drive Types Are Not Affected  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-15166098935>

Applies to:

StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

T10000C FSC_2B31 SNO with multiple drives.  Code level 3.62.112 and 3.63.101 are affected.  This article is just for T10000C drive.  Other T10000 drives are not affected.

Changes

 N/A

Cause

Code inspection has found an issue with how the FCP interface code is cleaning up all of the Verify command status flags during Abort processing.
It is believed that not cleaning up properly after the Abort is causing a subsequent Verify command to fail because it is reacting to bad left over status information.

Solution

Bug 26391408 - T10KC FSC_2B31 SNO with multiple drives.

Issue resolved with this firmware version:

Product      Version         Release_Date          Customer_Installable           Patch_ID
T10000C    3.64.101         08/22/2017                       Yes                         26639034

 

References

<BUG:26391408> - T10KC FSC_2B31 SNO WITH MULTIPLE DRIVES

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback