![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2300750.1 : Fujitsu M10-1/M10-4/M10-4S Servers: The Versions are Different After Performing a Flashupdate
In this Document
Created from <SR 3-15537923651> Applies to:Fujitsu M10-4 - Version All Versions and laterInformation in this document applies to any platform. SymptomsThe output from the XCP command "version -c xcp -v" shows different versions between the current and reserve banks. Example: XSCF> version -c xcp -v
BB#00-XSCF#0 (Master)
XCP0 (Current): 2340
CMU : 02.34.0000
POST : 3.13.0
OpenBoot PROM : 4.38.5+2.23.0
Hypervisor : 1.4.13
XSCF : 02.34.0000
XCP1 (Reserve): 2340
CMU : 02.33.0000
POST : 3.13.0
OpenBoot PROM : 4.38.5+2.21.0
Hypervisor : 1.4.12
XSCF : 02.34.0000
CMU BACKUP
#0: 02.34.0000
#1: 02.33.0000
ChangesUpdated to a new version of XCP on the M10 XSCFU CauseThis is normal for a system that was updated while the ppar was powered on. SolutionThere is no issue with running a system in this manner. The versions can be sync'ed by powering off the ppars and redoing the flashupdate with the "-f" option. Example: flashupdate -c update -m xcp -s 2340 -f Note: After performing a flashupdate the PPAR(s) will need to be poweroff/poweron to use the new versions of POST, Hypervisor, and OBP.
See documents 1554086.1 to find the current version of M10 XCP.
References<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information<NOTE:2105781.1> - M10 / M12 - How to update XCP firmware <NOTE:2047847.1> - Fujitsu M10: Firmware for the Various Hardware Components used on Fujitsu M10 <NOTE:1924671.1> - Fujitsu M10 PCI Expansion Unit Firmware Version Matrix Information Attachments This solution has no attachment |
||||||||||||||||||||
|