Solution Type Problem Resolution Sure Solution 2299632.1 : SL8500 - Left Side Robots Failing Fetch Cartridge and Puts to the Elevator
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsBot 1.2.0.1.0 was logging multiple 3955's on a Fetch Cartridge command with Error from device Code: 502 - Robot can not find target with result code of 5416.. (FSC Match Found in Rev. FRS851) Targeting packet received from scanner too short to contain valid data.. All fetchCartridge attempts were at the left side elevator address 1,2,-30,2,2 Excerpt from log snapshot for bot 1.2.0.1.0 1.2.0.1.0, root, default, CartridgeMov, -1042301, error, 3955, "Error from device Code: 502 - Robot can not find target", Data=<response sequence="8953242" final="true"><command>fetchCartridge</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5416</resultCode><resultText><!|CDATA|cmo_calibrate failed to find target for address (LRCSR) 1,2,-30,2,3 after 4 attempts, cmo_status=3; End of Text||></resultText><operationalState>502</operationalState></resultStatus><address>1,2,-30,2,3</address><trackPosMils>3856</trackPosMils></result></response> Device.db indicated the following state for the left side elevator... indicating that 3 cartridges were currently in the elevator carriage. 1,0,-30,2,0 HBB 74034805 false false false Ready hbza 3 true,true,true,false 18712101,18704901,18713701,0 Bot 1.3.0.1.0 was also logging the same errors all at the same elevator location when trying to perform put and fetchCartridge commands. Excerpts from error log for bot 1.3.0.1.0 1.3.0.1.0, root, hli0, move, 18734401, error, 3955, "Error from device Code: 502 - Robot can not find target", Data=<response sequence="8953911" final="true"><command>putCartridge</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5416</resultCode><resultText><!|CDATA|cmo_calibrate failed to find target for address (LRCSR) 1,3,-30,2,4 after 4 attempts, cmo_status=3; End of Text||></resultText><operationalState>502</operationalState></resultStatus><address>1,3,-30,2,4</address><trackPosMils>3853</trackPosMils></result></response> 1.3.0.1.0, root, default, CartridgeMov, -1043101, error, 3955, "Error from device Code: 502 - Robot can not find target", Data=<response sequence="8953715" final="true"><command>fetchCartridge</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5416</resultCode><resultText><!|CDATA|cmo_calibrate failed to find target for address (LRCSR) 1,3,-30,2,1 after 4 attempts, cmo_status=3; End of Text||></resultText><operationalState>502</operationalState></resultStatus><address>1,3,-30,2,1</address><trackPosMils>3845</trackPosMils></result></response>
CauseBroken left side elevator carriage assembly, P/N 313854502 [F] 4 Cell Array, Elevator
SolutionReplace the Elevator carriage assembly per Service Manual instructions. See ... SL8500 Service Manual http://amomv0115.us.oracle.com/archive/cd_ns/E23728_17/en/E23727/E23727_18.pdf If your SL8500 still has the turntable carriage located below the elevator assembly, that 4 cell carriage can be used in the elevator.
Attachments This solution has no attachment |
||||||||||||||||
|