Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2299283.1
Update Date:2017-08-24
Keywords:

Solution Type  Problem Resolution Sure

Solution  2299283.1 :   SL3000 - Firmware Upgrade With TLOAD 3.0 : Read Block Limits Cmmand Failed  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-15512991651>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Firmware upgrade with TLOAD 3.0 for Linux to IBM LTO6/SL3000

Message error during firmware upgrade:

Read Block Limits command failed
Download not performed

Cause

Drives are possibly reserved by backup software (Host).

Solution

Used the command below:

"\tload [-verbose] [-update] filename\n"

Example:

===> /tmp/TLOAD/p25178665_100_Generic/TLOAD_Dir/x86-linux/tload /tmp/TLOAD/p25178665_100_Generic/LTO6_G9P2.fcp_fh_OEMS.fmrz

Before the firmware upgrade, give a reboot on the tape drive by SLConsole (Diagnostic/Drive Folder:).


 

 

References

<NOTE:2188019.1> - Quick Reference Guide: How To Upgrade Firmware on HP & IBM LTO Drives via Data Path Using Tload and WinTload Utilities
<NOTE:2129671.1> - HP / IBM LTO - How To Upgrade the Firmware on the HP & IBM LTO Drives Using the Tload and WinTload Utilities

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.