![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2299283.1 : SL3000 - Firmware Upgrade With TLOAD 3.0 : Read Block Limits Cmmand Failed
In this Document
Created from <SR 3-15512991651> Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsFirmware upgrade with TLOAD 3.0 for Linux to IBM LTO6/SL3000 Message error during firmware upgrade: Read Block Limits command failed CauseDrives are possibly reserved by backup software (Host). SolutionUsed the command below: "\tload [-verbose] [-update] filename\n" Example: ===> /tmp/TLOAD/p25178665_100_Generic/TLOAD_Dir/x86-linux/tload /tmp/TLOAD/p25178665_100_Generic/LTO6_G9P2.fcp_fh_OEMS.fmrz Before the firmware upgrade, give a reboot on the tape drive by SLConsole (Diagnostic/Drive Folder:).
References<NOTE:2188019.1> - Quick Reference Guide: How To Upgrade Firmware on HP & IBM LTO Drives via Data Path Using Tload and WinTload Utilities<NOTE:2129671.1> - HP / IBM LTO - How To Upgrade the Firmware on the HP & IBM LTO Drives Using the Tload and WinTload Utilities Attachments This solution has no attachment |
||||||||||||||||||
|