![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2298721.1 : LTO - Can't Connect to Newer Belisarius Encryption Adapter Cards with VOP on IBM LTO4 and Higher Drives
In this Document
Applies to:IBM LTO4 Tape Drive - Version All Versions to All Versions [Release All Releases]IBM LTO7 Tape Drive - Version All Versions to All Versions [Release All Releases] IBM LTO6 Tape Drive - Version All Versions to All Versions [Release All Releases] IBM LTO5 Tape Drive - Version All Versions to All Versions [Release All Releases] Sun StorageTek Multi-Drive Virtual Op Panel - Version 2.1 and later Information in this document applies to any platform. SymptomsLTO - Can't Connect to Newer Belisarius Encryption Adapter Cards with VOP on IBM LTO4 and Higher Drives ChangesFirmware of Belisarius card was updated to 5.32.20.40. Belisarius card was recently replaced. CauseOlder versions of VOP won't connect to Belisarius cards running the latest firmware of 5.32.20.40. This could be because the Belisarius cards were recently upgraded to 5.32.20.40 or because the Belisarius card had to be replaced and the new replacement Belisarius card came in with 5.32.20.40 firmware on it. SolutionVOP 2.3.3 is required for Belisarius cards running 5.32.20.40. Attachments This solution has no attachment |
||||||||||||||||||
|