Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2297869.1
Update Date:2017-08-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  2297869.1 :   SL8500 - One Rail Has No Power and the Robots Won't Initialize  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Not sure if this should be partner or external. Customers generally don't touch the HBS.
Created from <SR 3-15543623271>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Rail has no power and robots will not initialize on that rail.

All other rails are working.

The last errors in the HBC log are:

2017-08-14T04:36:36.377, 1.2.0.2.0, root, default, SL8500, -1030101, info, 3821, "Servos off"
2017-08-14T04:37:06.408, 1.2.0.1.0, root, default, SL8500, -1030101, info, 3822, "Move and push"

No other errors in logs to indicate a problem.

Cause

Check for a power issue to the rail.  In this case, the HBS breaker was flipped.

Solution

Flip the HBS breaker to the "on" position and verify the power LED lights up.


Attachments