Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2296630.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2296630.1 :   SNMP And SSH Access Lost After Upgrade To ECZ730 From ECZ640  


Related Items
  • Acme Packet 4500
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  


SNMP and SSH connectivity is lost after upgrade to ECZ730 from ECZ640

In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-15515891641>

Applies to:

Acme Packet 4500 - Version E-Cx6.4.0 to E-Cz7.4.0 [Release E-Cx6.0 to E-Cz7.0]
Information in this document applies to any platform.

Symptoms

Management traffic (SSH and SNMP) stopped working after upgrade from 6.x to 7.x.

Cause

The upgrade from vxworks-based images (6.x release) to linux-based images (7.x release) requires attention to default-gateway and host route configuration.

Solution

 

After migration to Linux we actually honor the gateways set for each interface more strictly. So the route tables have a gateway for each media interface. The default-gateway applies to the management interfaces (i.e. - wancom0) beyond 7.2.

So customers should update their config to have same default-gateway as per the wancom0 subnet.

Here is an example from one of our lab -

3800-2(configure)# bootparam

'.' = clear field; '-' = go to previous field; q = quit

boot device : eth0
processor number : 0
host name : abcd.xyz
file name : /code/images/nnECZ730m2p1.32.bz
inet on ethernet (e) : aa.bb.cc.dd:ffffff00
inet on backplane (b) :
host inet (h) : xx.yy.zz.xx
gateway inet (g) : aa.bb.cc.1 -------------------------> This will be same as default-gateway
user (u) : vxftp
ftp password (pw) (blank = use rsh) : vxftp
flags (f) : 0x8
target name (tn) : sbc-lab
startup script (s) :
other (o) :

3800-2# show running-config system-config
system-config

comm-monitor
state disabled
sbc-grp-id 0
tls-profile
qos-enable enabled
call-trace disabled
internal-trace disabled
log-filter all
default-gateway aa.bb.cc.1 -----------------> This will be same as gateway of management interface or wancom0
restart enabled

 

Note :- This is applicable to SCZ versions also as the vxworks to linux migration was done for both ECZ and SCZ version .

 

 

References

<BUG:24968404> - CANNOT ACCESS WANCOM0 AFTER UPGRADING TO ECZ730M2P1

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.