Asset ID: |
1-72-2285503.1 |
Update Date: | 2017-07-12 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2285503.1
:
SL3000 - Is There Any Operational Impact on the SL3000 When Updating to Z/OS Z13 Driver 22 To 27
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-15265227401>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
none
Changes
Customer updating Z/Os Z13 to driver 22 to 27
Cause
Plan to upgrade driver
Solution
Interop Engineerings is currently running Z13 with driver=27, bundle=S31a, EC=P00339 and have been on this microcode level since October 27, 2016. No issues have been experienced with this current version...
References
<NOTE:1449301.2> - Information Center: Sun StorageTek SL3000 Modular Library System
Attachments