Solution Type Problem Resolution Sure Solution 2284890.1 : T10000 - Diagnostic FDE Extended Write Test Fails
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions and laterSun StorageTek T10000A Tape Drive - Version All Versions and later Sun StorageTek T10000B Tape Drive - Version All Versions and later StorageTek T10000C Tape Drive - Version All Versions and later StorageTek T10000D Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsThe extended write test fails: I received the same error: 8:35 AM Jun 30, 2017 - Connecting to 10.80.53.97 FDE: host_test_path parameter longer than buffer (80 bytes including NULL termination) 8:38 AM Jun 30, 2017 - END C:\Program Files (x86)\Multi Drive VOP CSE\diags\117\T10KB_Extended_Write_Test.117 Test Changes
CauseError: FDE: host_test_path parameter longer than buffer (80 bytes including NULL termination)
The name exceeds the max limit for characters. SolutionReduce the number of characters in the test name:
The below example is for T10000B. Go to this path on your laptop: C:\Program Files (x86)\Multi Drive VOP CSE\diags\117 Change the name for the extended write test to something like: T10KB_EW_Test.117 Attachments This solution has no attachment |
||||||||||||||||||
|