Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2284156.1
Update Date:2017-07-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  2284156.1 :   IB SWITCH FW downgrade from 2.1.8-1 to 2.1.6-2 DNS configuration disappeared  


Related Items
  • Exadata X4-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-14370596591>

Applies to:

Exadata X4-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

IB switches downgrade firmware from 2.1.8-1 to 2.1.6-2.

Downgrade should preserve the existing configuration.But after the downgrade, the nameservers in /etc/resolv.conf have been deleted.

Changes

 IB SWITCH firmware downgrade from 2.1.8-1 to 2.1.6-2.

Cause

This issue was investigated in the following INTERNAL bug.

Bug 24837124 - 12.1.2.3.3 ROLLBACK FROM 2.1.8-1 TO 2.1.6-2 REMOVES NAMESERVER ON IB SWITCH
 
Some config files like resolv.conf which are missed to be preserved on downgrade from 2.1.8 to 2.1.6.
 

Solution

The workaround is to manually add nameservers.
 

References

<BUG:24837124> - 12.1.2.3.3 ROLLBACK FROM 2.1.8-1 TO 2.1.6-2 REMOVES NAMESERVER ON IB SWITCH

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.