Solution Type Problem Resolution Sure Solution 2282838.1 : V215/V245 Fails POST with Faulty Power Up Reset Sequence!
In this Document
Created from <SR 3-15208287931> Applies to:Sun Fire V245 Server - Version All Versions to All Versions [Release All Releases]Sun Fire V215 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsSystem fails POST with the following message: 0>FATAL ERROR!!\
Power supplies have been checked, reseated, swapped and re-checked, the symptoms persisted. The PDB and associated cables have also been checked, and no issues found. CauseIssue is likely caused by a problem on one of the power rails on the MB, once PSU issues have been discarded. SolutionPlease verify the power supplies have no issues, the cable and outlet are working as intended and that they have the green power LEDs on. If no PSU issues found, cause is likely to be the MB. Please open a new service request with Oracle Support to verify. Attachments This solution has no attachment |
||||||||||||||||
|