Solution  2282838.1 :   V215/V245 Fails POST with Faulty Power Up Reset Sequence!  


Related Items
  • Sun Fire V245 Server
  •  
  • Sun Fire V215 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-15208287931>

Applies to:

Sun Fire V245 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V215 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 System fails POST with the following message:

0>FATAL ERROR!!\
0>ERROR: Faulty Power Up Reset Sequence!\
0>AFAR 00000000.00000000\
0>JBUS config reg = 03fa3f3e.104001ea.\
0>L2Cache CSR reg = 00000000.00f04000.\
0>FIRE JBUS CSR 00000ff5.13cb6000\
0>JBC Error Status Clear 00000000.00004020\
0>JBC Fatal Error log1 reg 00040112.2971a2c1\
0>JBC Fatal Error log2 reg 0006d249.211c7fc0\
0>JBC Error Status Clear reg 00000000.00004020\

 

Power supplies have been checked, reseated, swapped and re-checked, the symptoms persisted.

The PDB and associated cables have also been checked, and no issues found.

Cause

 Issue is likely caused by a problem on one of the power rails on the MB, once PSU issues have been discarded.

Solution

Please verify the power supplies have no issues, the cable and outlet are working as intended and that they have the green power LEDs on.

If no PSU issues found, cause is likely to be the MB. Please open a new service request with Oracle Support to verify.