Asset ID: |
1-72-2281427.1 |
Update Date: | 2017-06-29 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2281427.1
:
SL3000/IBM LTO6 - 3955 "Error from device Code: 604 - Drive is not functional", Data=|CDATA|drive 1,1,4,1,1: getState FAILED, resultCode = 6402| notCommunicating
Related Items |
- Sun StorageTek SL3000 Modular Library System
- IBM LTO6 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-15155256311>
Applies to:
IBM LTO6 Tape Drive - Version All Versions and later
Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
SL3000/SLConsole the drive is showing not Communicating.
The customer lost connection between backup software and tape drive.
Cause
Drive BAY 1 not communicating.
1.1.4.1.1 1 10WT036704 0464970+1404D70118 IbmUltrium6 IBM notCommunicating G350 ok N/A
2017-06-19T07:52:36.358 error 1.1.4.1.1 3955 "Error from device Code: 604 - Drive is not functional", Data=|CDATA|drive 1,1,4,1,1: getState FAILED, resultCode = 6402| notCommunicating
2017-06-19T07:52:39.131 warn 1.0.0.0.0 9995 "Reboot requested - local request", parameters="client=localhost, device=1,1,4,1,1, requester=default, complexWide=false"
2017-06-19T07:52:39.146 error 1.1.4.1.1 3204 "System error - Invalid state transition", state=Error transtion=Vary offline reboot
2017-06-19T08:03:43.335 error 1.1.4.1.1 3955 "Error from device Code: 604 - Drive is not functional", Data=|CDATA|drive 1,1,4,1,1: Power up FAILED, resultCode = 6411 (state = inoperative)|| reboot
Solution
1. Tried the reboot of the drive and the still occurring.
2. Re-plugged all connectors in the Drive Tray and solved the problem.
Attachments
This solution has no attachment