Asset ID: |
1-72-2281369.1 |
Update Date: | 2018-05-17 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2281369.1
:
T10000C/T10000D - FSC 6106 6112 The Record Read From The Tape Could Not Be Decrypted. After firmware upgrade to T10KC/D 3.63.101 and 4.12.106
Related Items |
- StorageTek T10000D Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
After firmware upgrade to T10KC/D 3.63.101 and 4.12.106
FSC 6106/6112 create automated SRs (ASRs) when connected to SDP2 erver
In this Document
Created from <SR 3-15011383831>
Applies to:
StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
ASR received regarding MODEL = T10000D
FSC = 6112
Changes
T10000D firmware upgrade from 4.11.113 to 4.12.106
T10000C firmware upgrade from 3.62.112 to 3.63.101
Cause
with firmware level FSC 6101 and 6112 are reported as PERM error rather than as a TEMP error with firmware level 4.11.113
This creates ASR spam alerts via SDP2.
Solution
Install special build firmware RB4.12.106 for T10000D and RB3.63.101 for T10000C.
This microcode addresses a known issue with accounts that use DPKM for encrypting tapes where the host sends the wrong key to the drive and the drive posts either 6101 or 6112 FSC.
Attachments
This solution has no attachment