In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-15125324311>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Log snapshot is showing Load error to differents cartridges.

 "Error from device Code: 601 - Drive is loaded", Data=|CDATA|drive 1,4,2,1,1: rewindUnload FAILED with unitCheck 5B5B - drive is loaded (cartLabel = P04329T1, driveType = T10000b, driveFirmware = 1.52.206-5.30)||
 "Warning from device", Data=|CDATA|drive 1,4,2,1,1: rewindUnload Successful with mediaError: Cartridge Label: P01717T1, FSC: 5B5B||
 "Error from device Code: 601 - Drive is loaded", Data=|CDATA|drive 1,4,2,1,1: rewindUnload FAILED with unitCheck 5B5B - drive is loaded (cartLabel = P05072T1, driveType = T10000b, driveFirmware = 1.52.206-5.30)||
 "Error from device Code: 601 - Drive is loaded", Data=|CDATA|drive 1,4,2,1,1: rewindUnload FAILED with unitCheck 5B5B - drive is loaded (cartLabel = P05072T1, driveType = T10000b, driveFirmware = 1.52.206-5.30)||

Cause

Cartridge Stuck on Drive..

MODEL = T10000B
FSC = 5B5B
(FSC Match Found in Rev. 1.52)
FSC: 5B5B ELEV_FSC_UNBUCKLE_MOTION_TIMEOUT
MIM Code: NONE
FRU: HARDWARE CONF: 100%
Summary: |ELEVATOR |INTERCONNECT |POWER AMP |
Field Text:
A timeout occurred while unbuckling the cartridge leader from the buckler.
 

Solution

Replaced the Tape Drive.
 