Solution Type  Problem Resolution Sure

Solution  2279098.1 :   T10000A/B - FSC 48CE with microcode 1.52.206  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-15063904721>

Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

ECAM ERROR CC=5 RC=108  ==== > FSC 48CE

.SLS6684I RTD V1150F9C ON VTSS VSM115 RETURNED ECAM ERROR CC=5 RC=108
.SLS6625E RTD V1150F9C REPORTED END OF DATA: 0840203618CC3E20370048CE350B0000000006E002C01040CE0E522068570000
 OPSIST * OCORR. SLS6625E - .SLS6625E RTD V1150F9C REPORTED END OF DATA: 0840203618CC3E20370048CE350B0000000006E002C01040CE0E5
 OPFITO * OCORR. SLS6625E - .SLS6625E RTD V1150F9C REPORTED END OF DATA: 0840203618CC3E20370048CE350B0000000006E002C01040CE0E5

Cause

Read Error with FSC 48CE on microcode 1.52.206.

MODEL = T10000B
FSC = 48CE
(FSC Match Found in Rev. 1.52)

FSC: 48CE RO_FSC_READ_TARGET_ENCOUNTERED_EOD

MIM Code: NONE

FRU: OPER. ERROR CONF: 100%

Summary: |EOD FOUND PRIOR |TO TARGET | *** |

Field Text:
The read code encountered end of data while looking for a requested target.

 

Solution

Replace the tape drive (T10000B).