Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2277915.1
Update Date:2017-12-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  2277915.1 :   Exalogic Exapatch Infiniband Gateway (NM2-GW) PSU Error - "Insufficient free space on /var/log"  


Related Items
  • Oracle Exalogic Elastic Cloud Software
  •  
  • Exalogic Elastic Cloud X5-2 Quarter Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exalogic/OVCA>Oracle Exalogic>MW: Exalogic Core
  •  




In this Document
Symptoms
Cause
Solution
 Workaround:
 Solution:
References


Created from <SR 3-15133214051>

Applies to:

Oracle Exalogic Elastic Cloud Software - Version 2.0.6.2.0 and later
Exalogic Elastic Cloud X5-2 Quarter Rack - Version X5 to X5 [Release X5]
Information in this document applies to any platform.

Symptoms

During the exapatch prepatch checks for Infiniband Gateway Switch (NM2-GW) patching, the following error was found in the exapatch log:

ERROR: Insufficient free space on /var/log (Found 0 KB; Required 1000 KB)

Cause

This is caused by Bug 25664363 - /var/log/lumain.log not rotated

Solution

Workaround:

On each gateway switch, run the following 2 commands to clear and verify space is now freed up:

# echo > /var/log/lumain.log
# df -kh | grep var

There are only dots and dashes in that log so there is no reason to back up the file.

Solution:

Apply the July 2017 PSU which includes the firmware version 2.2.5-3 for the NM2-GW switch containing a permanent fix.

References

<BUG:26289260> - EXALOGIC : 100% SPACE USED BY /VAR/LOG ON NM2-GW
<NOTE:2276658.1> - Exadata/Exalogic IB switches fail to locate the Subnet Manager, "No Master SubnetManager Seen In The System"
<BUG:25664363> - /VAR/LOG/LUMAIN.LOG NOT ROTATED

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.