![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2277915.1 : Exalogic Exapatch Infiniband Gateway (NM2-GW) PSU Error - "Insufficient free space on /var/log"
In this Document
Created from <SR 3-15133214051> Applies to:Oracle Exalogic Elastic Cloud Software - Version 2.0.6.2.0 and laterExalogic Elastic Cloud X5-2 Quarter Rack - Version X5 to X5 [Release X5] Information in this document applies to any platform. SymptomsDuring the exapatch prepatch checks for Infiniband Gateway Switch (NM2-GW) patching, the following error was found in the exapatch log: CauseThis is caused by Bug 25664363 - /var/log/lumain.log not rotated SolutionWorkaround:On each gateway switch, run the following 2 commands to clear and verify space is now freed up: # echo > /var/log/lumain.log
# df -kh | grep var There are only dots and dashes in that log so there is no reason to back up the file. Solution:Apply the July 2017 PSU which includes the firmware version 2.2.5-3 for the NM2-GW switch containing a permanent fix. References<BUG:26289260> - EXALOGIC : 100% SPACE USED BY /VAR/LOG ON NM2-GW<NOTE:2276658.1> - Exadata/Exalogic IB switches fail to locate the Subnet Manager, "No Master SubnetManager Seen In The System" <BUG:25664363> - /VAR/LOG/LUMAIN.LOG NOT ROTATED Attachments This solution has no attachment |
||||||||||||||||||||||
|