Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2277509.1
Update Date:2018-03-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  2277509.1 :   Oracle ZFS Storage Appliance: Appliance BUI unavailable after Upgrade To 2013.1.7.0  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-14939246101>

Applies to:

Oracle ZFS Storage ZS5-4 - Version All Versions and later
Oracle ZFS Storage ZS5-2 - Version All Versions and later
Oracle ZFS Storage ZS4-4 - Version All Versions and later
Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

After upgrading to Appliance Firmware Release 2013.1.7.0 (OS8.7.0), the BUI is not available.

 

Error is received regardless of the browser used (Firefox, Internet Explorer and Chrome).

Example error message:

    Firefox can’t establish a connection to the server at zfs01a-mgmt.com:215.

 

Tested with wget:

And with wget:
rhtst1:cbdba4:/home/cbdba4> wget zfs01a-mgmt.com:215
--2017-05-19 12:59:05-- http://zfs01a-mgmt.com:215/
Resolving zfs01a-mgmt.com... 192.168.116.44
Connecting to zfs01a-mgmt.com|192.168.116.44|:215... failed: Connection refused.

 

 

Changes

OS upgraded to 2013.1.7.0

 

Cause

Bug 25913987 (ZFSSA BUI unavailable if interface name is subset of ipmp test address name)

 

The problem was caused because - in a previous intervention - a network interface was created on stripped node after a motherboard replacement, so the cluster does not have the correct information.

The problem is believed to occur because configuration changes were done while the cluster head was in stripped state instead of clustered status.

 

 

Solution

Issue resolved by creating a 'new' VNIC over the same datalink to be able to access to admin interface through the BUI.

To clear all 'remnants' of the issue, the  cluster has to be in the clustered status - to be able to delete the previous unusable VNIC.

 

 

References

<BUG:25913987> - ZFSSA BUI UNAVAILABLE IF INTERFACE NAME IS SUBSET OF IPMP TEST ADDRESS NAME

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.