Solution Type  Problem Resolution Sure

Solution  2276191.1 :   Oracle ZFS Storage Appliance: SMU throws errors after upgrade to OS 8.7.4  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun ZFS Backup Appliance
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  


SMU throws errors after upgrade of ZFSSA to OS8.7.4

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-15101365221>

Applies to:

Sun ZFS Storage 7420 - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
Sun ZFS Backup Appliance - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

Oracle Snap Management Utility (SMU) throws errors after upgrade of ZFSSA to OS8.7.4

Jun 12, 2017 8:34:50 AM com.oracle.smu.server.ExecutableDeleteCommand exec

WARNING: Connecting to the storage failed: storage nas1107 login: Session.connect: java.io.IOException: End of IO Stream Read
Jun 12, 2017 8:34:50 AM com.oracle.smu.server.jpa.JPATasks$2 run
SEVERE: task failed

 

Changes

Upgrade of ZFS Storage Appliance from OS 8.6.8 to OS 8.7.4

 

Cause

Java incompatibility issue.

Prior to Java 8, Java did not support key sizes greater than 1024 bits for diffie-hellman keys. OS 8.7 SSHD requires keys larger than 1K.

 

Solution

The only option is to upgrade the system running SMU to Java 8.

 

References

<BUG:25899589> - JSCH COMPATIBILITY ISSUE WITH OS 8.7
<NOTE:2022677.1> - Sun Storage 7000 Unified Storage System : HOW TO make SMU use the 'right' network interface