![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2276054.1 : T10000 - 40AC And 40AD Errors
In this Document
Applies to:StorageTek T10000C Tape Drive - Version All Versions and laterStorageTek T10000D Tape Drive - Version All Versions and later Sun StorageTek T10000 Tape Drive - Version All Versions and later Sun StorageTek T10000A Tape Drive - Version All Versions and later Sun StorageTek T10000B Tape Drive - Version All Versions and later Information in this document applies to any platform. Symptoms40AC and 40AD informational error codes. Changes
CauseThe tape drive was commanded to read into the End Of Data Marker. Solution40AC and 40AD error code is produced when the tape drive is commanded to read into the End Of Data marker. (EOD marker) They are informational and do not indicate that there is a problem with the tape drive. Some applications will read into the EOD marker to verify position before appending further data to the tape. 40AC and 40AD informational error codes can be ignored and do not cause any problem for the job. Attachments This solution has no attachment |
||||||||||||||||||
|