Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2276054.1
Update Date:2017-06-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2276054.1 :   T10000 - 40AC And 40AD Errors  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

StorageTek T10000C Tape Drive - Version All Versions and later
StorageTek T10000D Tape Drive - Version All Versions and later
Sun StorageTek T10000 Tape Drive - Version All Versions and later
Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 40AC and 40AD informational error codes.

Changes

 

Cause

 The tape drive was commanded to read into the End Of Data Marker.

Solution

40AC and 40AD error code is produced when the tape drive is commanded to read into the End Of Data marker. (EOD marker)  They are informational and do not indicate that there is a problem with the tape drive. Some applications will read into the EOD marker to verify position before appending further data to the tape. 40AC and 40AD informational error codes can be ignored and do not cause any problem for the job.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.