![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2275132.1 : ODA IOCALIBRATE Shows a Very Slow Performing Disk at 1/2 of IO other Disks but Still Shows No Errors : oakcli validate -c DiskCalibration
In this Document
Created from <SR 3-14861589971> Applies to:Oracle Database Appliance X3-2 - Version All Versions to All Versions [Release All Releases]Oracle Database Appliance - Version All Versions to All Versions [Release All Releases] Oracle Database Appliance X4-2 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsAfter re-deployed the ODA, running 'oakcli validate -c DiskCalibration' detected a substandard performing disk 'oakcli validate -c DiskCalibration'
RESULT: Random read throughput of HDD_E0_S15_376391396 is 234 IOPS 147 MBPS RESULT: Random read throughput of HDD_E0_S17_376391424 is 238 IOPS 153 MBPS RESULT: Random read throughput of HDD_E0_S07_376390852 is 235 IOPS 148 MBPS RESULT: Random read throughput of HDD_E0_S04_376390396 is 227 IOPS 147 MBPS RESULT: Random read throughput of HDD_E0_S01_376391436 is 238 IOPS 151 MBPS RESULT: Random read throughput of HDD_E0_S05_376762192 is 237 IOPS 147 MBPS RESULT: Random read throughput of HDD_E0_S10_376762548 is 204 IOPS 130 MBPS RESULT: Random read throughput of HDD_E0_S09_376718004 is 230 IOPS 144 MBPS RESULT: Random read throughput of HDD_E0_S12_376762224 is 234 IOPS 152 MBPS RESULT: Random read throughput of HDD_E0_S18_376762524 is 237 IOPS 148 MBPS RESULT: Random read throughput of HDD_E0_S14_376762520 is 236 IOPS 150 MBPS RESULT: Random read throughput of HDD_E0_S00_376391324 is 232 IOPS 145 MBPS RESULT: Random read throughput of HDD_E0_S13_376515908 is 234 IOPS 149 MBPS RESULT: Random read throughput of HDD_E0_S06_376762276 is 238 IOPS 149 MBPS RESULT: Random read throughput of HDD_E0_S03_376516984 is 235 IOPS 148 MBPS RESULT: Random read throughput of HDD_E0_S19_376391432 is 231 IOPS 151 MBPS RESULT: Random read throughput of HDD_E0_S16_376391480 is 224 IOPS 82 MBPS <RESULT: Random read throughput of HDD_E0_S08_376390936 is 229 IOPS 146 MBPS RESULT: Random read throughput of HDD_E0_S11_376390800 is 232 IOPS 147 MBPS RESULT: Random read throughput of HDD_E0_S02_376391428 is 233 IOPS 149 MBPS
# oakcli stordiag e0_pd_16 --> No issues # smartctl --all /dev/sdao --> No issues
No direct errors was seen for the disk smartctl --all /dev/sdao Vendor: HITACHI Current Drive Temperature: 25 C Error counter log: Non-medium error count: 0 This is a clean test with no evidence of a problem ChangesNone: This was an older ODA that was deployed for the first time after sitting on the shelf a few years. CauseThe disk need replaced. Solution1. Replace the disk References<NOTE:2268148.1> - Disk reporting low IOPS and MBPS - ODAAttachments This solution has no attachment |
||||||||||||||||||||
|