Asset ID: |
1-72-2273582.1 |
Update Date: | 2017-07-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2273582.1
:
SL8500 - SLS0665E ACS 02 DEGRADED, LSM 02:01, CONDITION 2, Error 5051 "A Low Voltage Condition Has Been Detected on the Servo Motor Power
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Handbot reach amp errors
Created from <SR 3-15045746751>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
During a put the following error occurs.
Robot hand 1.2.0.1.0 failure
956: 2017-06-03T02:53:47.974, 1.2.0.1.0, root, default, RobotInitial, -1021501, error, 3955, "Error from device Code: 514 - Robot needs to be reset", Data=moveUntilStallerror5051<!|CDATA|servo mech track event 5051 at 150175 tachs, 272044 mils||>514268
ERROR
Stuck tape in robot hand
1 2 0 1 0 robot 1 2 -15 2 7 readable ME1820T2 -1 0 1 1 99
BUSINESS IMPACT
-----------------------
The issue has the following business impact:
Due to this issue, users cannot use the library properly for move operations across rail 2 / 25% of the library moves.
Cause
The handbot servo motor might try to compensate for missed service intervals while moving along the track. This could be due to a problem with track alignment or may indicate a very busy controller that is not able to service the interrupt signals from the motors within the allotted time. The controller may send an error message regarding a low voltage condition that may not necessarily indicate a power issue per se but more of a power surge to compensate for a stalling robot.
-- Error 5051 means "A low voltage condition has been detected on the servo motor power"
Solution
Removed and replaced handbot due to reach amp errors.
Attachments
This solution has no attachment