Asset ID: |
1-72-2267973.1 |
Update Date: | 2017-05-19 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2267973.1
:
Diameter Signaling Router [DSR] - IPFE Menu Is Not Present On SOAM GUI, After Rollback From DSR 7.0.1 To 5.0
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-14291352931>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and later
Information in this document applies to any platform.
Symptoms
After rollback SO from DSR 7.0.1 to 5.0, the IPFE Configuration menu is not displayed anymore on the SO GUI.
Cause
Issue was caused due to Bug# 19911799
Bug 19911799 - BIE broken after upgrade due to symbolic link created in backout procedure
Solution
The workaround to fix the issue is:
ln –fs /usr/TKLC/ipfe/modules/ipfe / /var/TKLC/appworks/modules/ipfe
Another Bug# 25676494 has been opened to include this workaround in DSR 7.0 back out procedure in upgrade document.
References
<BUG:19911799> - BIE BROKEN AFTER UPGRADE DUE TO SYMBOLIC LINK CREATED IN BACKOUT PROCEDURE.
Attachments
This solution has no attachment