![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2267865.1 : T10000D - Unable To Poll a Drive through SNMP
In this Document
Created from <SR 3-14340431731> Applies to:StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsCustomer is unable to poll a T10000D tape drive through SNMP. Customer put the tape drive offline and checked the config on the tape drive, they see SNMP status DISABLED. NOTE: Customer has SDP v2.3.2 running. Customer checked tape drive settings via MDVOP customer version, which is 'sysadmin' and found that the SNMP setting is NOT visible with 'sysadmin', so the customer is unable to check if SNMP is disabled/enabled. Changes
CauseSNMP status DISABLED SolutionFSE used a CSE version of VOP. With this version the SNMP setting could be seen and changed. They were then able to set SNMP Enabled, IPL the tape drive, and put the drive back ONLINE. References<NOTE:1662397.1> - T10000 -SNMP Setup for SDP2Attachments This solution has no attachment |
||||||||||||||||||||
|