Asset ID: |
1-72-2267354.1 |
Update Date: | 2017-05-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2267354.1
:
sl8500 - FSC 3324, Audit Cannot Complete Due To Hardware Failure
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-14899545315>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
FSC 3324 "Audit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Cap unlocked", startAddress=1,3,55,1,1 endAddress=1,3,55,1,13
Changes
Cause
The audit of the CAP results in FSC 3324 when tapes are ejecting to the CAP at that time.
Solution
If an eject was occurring at the time of this FSC, then no action is needed. Once the eject completes then the audit will be able to complete without error.
Attachments
This solution has no attachment