![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2266308.1 : Oracle ZFS Storage Appliance: After upgrade to AK8.7.0, Analytics datasets become disabled after 10 days
In this Document
Created from <SR 3-14715629691> Applies to:Sun ZFS Storage 7120 - Version All Versions and laterOracle ZFS Storage ZS5-4 - Version All Versions and later Oracle ZFS Storage ZS5-2 - Version All Versions and later Oracle ZFS Storage ZS4-4 - Version All Versions and later Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsExisting analytic datasets were becoming disabled after 10 days from the last access date even though the dataset_auto_suspend setting was set to false.
ChangesRecent upgrade to AK8.7.0
CauseAK 8.7.0 added the new feature to auto suspend datasets, but does not update existing datasets with the required properties, this causes the system to default to a behavior that enables the auto suspend function.
SolutionEnable and then disable the dataset_auto_suspend function to update the dataset properties. analytics settings set dataset_auto_suspend=true
Or in the BUI, Navigate to analytics > settings and check the "Enable auto suspend policy" box , set the threshold to 1 hour, then click apply. Then un-check the "Enable auto suspend policy" box and click apply. This results in the datasets getting updated with the new properties and not becoming disabled after the default time of 10 days.
Attachments This solution has no attachment |
||||||||||||||||||
|