![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2264145.1 : T10000A - Multiple Key Processing Operations Were Attempted. Only One Operation Is Allowed At One Time FSC(6146)
In this Document
Created from <SR 3-14814917866> Applies to:Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. This problem occured on 3 other tape drives. Checked all of the cable connections. i just restarted both of the OKM servers. SymptomsSummary:Multiple key processing operations were attempted. Only one operation is allowed at one time. Fault event description:Multiple key processing operations were attempted. Only one operation is allowed at one time. CST_UNLOAD event. Multiple key processing operations were attempted. Only one o CauseT10000A/B - FSC 6146 SNO - This may be a result of certain set of tapes bringing out this SNO condition. Identify the tapes and remove them from service. 2017-05-02 10:47:25 Default: A drive fatal error (SNO) has occurred. These SNO (Should Not Occur) errors will cause the drive to stop communicating with the host and automatically force a drive dump. The drive will come back online after it IPLs. This action will cause the current tape job to terminate. Engage an L2 Tape Domain engineer to investigate and open a bug as this drive is running on current microcode. Support Actions
SolutionPropose to restart OKM servers