Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2263416.1
Update Date:2017-05-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2263416.1 :   LTO - Drive Not Coming Online, Current Health Status Sows as FATAL and via SLC Drive State Shows as Inoperative  


Related Items
  • LTO Tape Drive
  •  
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14813505961>

Applies to:

Sun StorageTek SL500 Modular Library System - Version All Versions and later
LTO Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

LTO3 drive not coming online. Current health status shows as FATAL and via SLC Drive state shows as Inoperative.

2017-05-02T11:45:16.830 error 0.0.0.0.0 0000 "IfmDriveGetConfig::issueCommand(): Drive Get Config Response Bad Result Code = 6406 For Drive ID 1"

Fatal Error

Cause

 Defective tape drive.

Solution

 Replaced tape drive.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback