Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2263343.1
Update Date:2017-05-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2263343.1 :   SL150 - Having Connectivity Issues Between SAN and the Tape Device  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14827705365>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

ur oracle tape library Storagetech150 is having connectivity issues between SAN and the device.
Troubleshooting steps done.

- Reboot the drive and check the status.: Done
- Check Fibre Channel cable connectivity, remove and reconnect the FC cable. Done
- Confirm the FC cable status by connecting to a different port on the SAN switch. Done
- Swap the not working port cable with a working port cable. Done

Symptoms

 150 is having connectivity issues between SAN and the device.

Cause

 Switch issue.

Solution

 Focused on SAN switch side and changed some parameter in order to force port to work using F-port type.

portcfggport -> this force's the port to pass the AL verification and only negotiates as an E or F port.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback