Solution Type  Problem Resolution Sure

Solution  2262180.1 :   RSC POST Failure Prevents System Booting  


Related Items
  • Sun Fire V490 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx90
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-13696504501>

Applies to:

Sun Fire V490 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Server won't reach ok prompt after power ON.  Stops after RSC POST failure.

Cause

The Console logs showing RSC post failed

==============================
ERROR: RSC POST TEST
H/W under test = Flash Memory Data
  Test name = FLASH CRC Test
  Subtest name = Main Sector Flash Test

  Failure: CRC Error - ReFlash EPROM.
  EPROM CRC: 98a2bebb Calced CRC: 4ede84ec

END_ERROR

Main Sectors FLASH CRC Test, FAILED. >>>>>>>>>>>>>
 

Solution

Action plan is to replace the RSC card
 