![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2260543.1 : SL150 - Down, 0465 - ROBOT_FRONT_VISION_FAILURE - Fault Code:9110
In this Document
Created from <SR 3-14762452081> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsSL150 down 0465 - ROBOT_FRONT_VISION_FAILURE - Fault Code:9110 Probable Failed Components Actions to Take CauseProbable Failed Components: SolutionActions to Take: The SL150 robot CRU needs to be replaced. 1473774.1 - SL150 - How to Remove/Replace the Robot CRU in a StorageTek SL150 Modular Tape Library [VCAP]