Solution Type  Problem Resolution Sure

Solution  2260543.1 :   SL150 - Down, 0465 - ROBOT_FRONT_VISION_FAILURE - Fault Code:9110  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-14762452081>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SL150 down
2017-04-25 23:53:31

0465 - ROBOT_FRONT_VISION_FAILURE - Fault Code:9110

Probable Failed Components
1. Robot

Actions to Take
Check for unseated tape.
Inspect/replace robot

Cause

Probable Failed Components:
1. Robot

Solution

Actions to Take:
Check for unseated tape.
Inspect/replace robot

The SL150 robot CRU needs to be replaced.

Partnum: 7308618
Parttype: Robot