Symptoms

eaglestp 17-03-03 11:40:16  EAGLE5 46.0.1-65.26.26
* 4489.0060 * CDT 16 Minor customer trouble detected
stpmos1a 17-03-03 11:59:59 MSK EAGLE5 46.0.1-65.26.26
** 0633.0082 ** FUSE PANEL 61xx Alarm in Fuse Panel

When removing the MASP B, the alarms clear. As soon as the MASP B is reinserted the alarms come back.

Cause

All connectors inside the control shelf and outside the control shelf have been checked : no pins bent, no damage, no corrosion,

The MASPs and MDAL have been strongly reinserted in the Eagle and checked that there was no lose connection.

A blower has been used to clean all connectors
 

Solution

 The issue cleared when cleaning with a blower the connectors of the MASP B inside the control shelf.