Solution Type Problem Resolution Sure Solution 2260268.1 : UAM 0060 Minor Customer Trouble Detected CDT 16
In this Document
Created from <SR 3-13704494241> Applies to:Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and laterInformation in this document applies to any platform. Symptomseaglestp 17-03-03 11:40:16 EAGLE5 46.0.1-65.26.26
* 4489.0060 * CDT 16 Minor customer trouble detected stpmos1a 17-03-03 11:59:59 MSK EAGLE5 46.0.1-65.26.26
** 0633.0082 ** FUSE PANEL 61xx Alarm in Fuse Panel When removing the MASP B, the alarms clear. As soon as the MASP B is reinserted the alarms come back. CauseAll connectors inside the control shelf and outside the control shelf have been checked : no pins bent, no damage, no corrosion, The MASPs and MDAL have been strongly reinserted in the Eagle and checked that there was no lose connection. A blower has been used to clean all connectors SolutionThe issue cleared when cleaning with a blower the connectors of the MASP B inside the control shelf. Attachments This solution has no attachment |
||||||||||||||||
|