![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2258392.1 : T10000C - SNO FSC: 091F
In this Document
Created from <SR 3-14435133661> Applies to:StorageTek T10000C Tape Drive - Version All Versions and laterInformation in this document applies to any platform. SymptomsT10000c Version: 3.62.111-5.50 Last Updated 2017-03-08 16:39:39 2017-03-08 15:21:35 Interface Type: FIBRE ip_address : 10.221.2.201 mim_flags : 01000006 SNMP Manager List (snmp_manager_ips): 2017-03-08 15:21:35 (SA-363) A drive fatal error (SNO) has occurred. These SNO (Should Not Occur) errors will cause the drive to stop communicating with the host and automatically force a drive dump. The drive will come back online after it IPLs. This action will cause the current tape job to terminate. Engage an L2 Tape Domain engineer to investigate and open a bug as this drive is running on current microcode. Current Available Microcode: 3.62.112 Changes
CauseFirmware issue. SolutionMoved to firmware 3.62.112 T10000/9840 - Upgrading Firmware on a Tape Drive (Doc ID 1680168.1) Created from <SR 3-14435133661> Applies to:StorageTek T10000C Tape Drive - Version All Versions and later Attachments This solution has no attachment |
||||||||||||||||||||||
|