Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2254236.1
Update Date:2017-04-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2254236.1 :   Diameter Signaling Router (DSR): Problems When Editing A Multi-homed Connection With SOAM-GUI.  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-14408760511>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.3.0 and later
Tekelec

Symptoms

When MPs (Message Processors) are configured as Active/Standby pair and a multihomed SCTP connection is edited, nothing is displayed on Alternate Local IP field.
Once click "ok" without changing anything the "Alternate Local IP Address" field vanishes.

Cause

Bug# 25835810 - GUI issue at edit connection screen with Multihome sctp connection.
 

Solution

As a work around use Bulk Import Export (BIE) to update the multihomed SCTP connection.
Permanent fix for Bug# 25835810 is in DSR 8.1
 

References

<BUG:25835810> - GUI ISSUE AT EDIT CONNECTION SCREEN WITH MULTIHOME SCTP CONNECTION

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback