Asset ID: |
1-72-2254236.1 |
Update Date: | 2017-04-11 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2254236.1
:
Diameter Signaling Router (DSR): Problems When Editing A Multi-homed Connection With SOAM-GUI.
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-14408760511>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.3.0 and later
Tekelec
Symptoms
When MPs (Message Processors) are configured as Active/Standby pair and a multihomed SCTP connection is edited, nothing is displayed on Alternate Local IP field.
Once click "ok" without changing anything the "Alternate Local IP Address" field vanishes.
Cause
Bug# 25835810 - GUI issue at edit connection screen with Multihome sctp connection.
Solution
As a work around use Bulk Import Export (BIE) to update the multihomed SCTP connection.
Permanent fix for Bug# 25835810 is in DSR 8.1
References
<BUG:25835810> - GUI ISSUE AT EDIT CONNECTION SCREEN WITH MULTIHOME SCTP CONNECTION