Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2251984.1
Update Date:2017-04-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  2251984.1 :   EPAP B RTDB Restore Failed For R16.1 Upgrade  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14625212551>

Applies to:

Oracle Communications EAGLE (Software) - Version EPAP 16.0 and later
Information in this document applies to any platform.

Symptoms

The RTDB restore is failing because the conversion is failing.

Cause

Conversion failing because of table file size. If the backup is compatible, but of a different table version, it will convert the tables after the restore completes. Part of that process is to check the size of the DN, IMEI, and IMSI tables. If any size matches the corresponding parameter, the convert will fail. In this case, DN table size matched the set parameter.

Solution

Restore with backup from site on EPAP 16.1


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.