Solution Type  Problem Resolution Sure

Solution  2251953.1 :   Frequent Troubles "HMRT_LS.C" For One Traffic Card In Particular  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14527174181>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

The traffic card 1202 in particular is frequently issuing the trouble below:

 

eaglestp 17-03-15 02:28:24 EST EAGLE 46.3.0.0.2-68.28.0
  Card 1202 Module hmrt_ls.c Line 5475 Class 01c3 Severity 1
  ff ff 01 00 1f 00 00 00 02 00 01 00 3f b4 15 d2 ............?...
  c6 b9 15 d2 18 9c 61 07 18 9c 61 07 01 00 01 00 ......a...a.....
  00 00 7a b8 09 0d 7a b8 ..z...z.

 

Cause

The frequent troubles "hmrt_ms.c" were due to the repeated bouncing of 2 destinations.
 
The trouble "hmrt_ls.c" is related to the route and link selection

****17-03-30 12:41:31****
0935.0314 DPC 01181 Route is allowed
****17-03-30 12:41:30****
0934.0316 DPC 01135 Route is prohibited
****17-03-30 12:41:30****
0931.0316 DPC 01181 Route is prohibited
****17-03-30 12:41:29****
0930.0314 DPC 01135 Route is allowed
****17-03-30 12:41:28****
0926.0314 DPC 01181 Route is allowed
****17-03-30 12:41:27****
0924.0316 DPC 01181 Route is prohibited
****17-03-30 12:41:27****
0921.0316 DPC 01135 Route is prohibited
****17-03-30 12:41:26****
0919.0314 DPC 01181 Route is allowed
****17-03-30 12:41:26****
0917.0314 DPC 01135 Route is allowed
****17-03-30 12:41:24****
0913.0316 DPC 01181 Route is prohibited
****17-03-30 12:41:24****
0912.0316 DPC 01135 Route is prohibited

...

 

Solution

Removing the primary route to both bouncing destinations (dlt-rte) stopped the bouncing.
As a result the frequent troubles "hmrt_ls.c" became very rare.

================================================================

 

 

 

 

 


 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.