Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2249672.1
Update Date:2017-12-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2249672.1 :   SL3000 - SCSI Element IDs Changed After A Firmware Upgrade To FRS_4.3x  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


SL3000 Library Fibre attached.

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-10615423061>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
This problem was discovered after chasing an auto-clean problem with an SL3000 partitioned library. SL3000 is Fibre attached.

Symptoms

After an upgrade to FRS_4.32 the scsi element ids have changed on drives and some drives had duplicate scsi element ids.

Cell reallocation in any of the Library partitions seems to cause auto-clean to be disabled for the partition.

Changes

FW upgrade to 4.32

Cause

FW FRS_4.32 in combination with SLC FRS_6.60 and cell re-allocation in library partitions

Solution

To resolve the scsi element ids issue post upgrade you need FW FRS_4.40 and SLC FRS_6.65