![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2247935.1 : T10000A/B/C/D - 376A errors
In this Document
Applies to:StorageTek T10000C Tape Drive - Version All Versions and laterStorageTek T10000D Tape Drive - Version All Versions and later Sun StorageTek T10000 Tape Drive - Version All Versions and later Sun StorageTek T10000A Tape Drive - Version All Versions and later Sun StorageTek T10000B Tape Drive - Version All Versions and later Information in this document applies to any platform. Symptoms376A Perm Errors. CauseFSC = 376A FSC: 376A RO_FSC_FALSE_EOD_EOW_MCF MIM Code: NONE FRU: MEDIA CONF: 50% FRU: HARDWARE CONF: 50% Summary: |OLD DATA SEEN |ERROR | *** | Field Text: Solution376A Perm Errors. While reading, old data was detected that requires error recovery to get over. 376A is an informational error code. It indicates that the job read past the End Of Data marker and is now in old data. This is possible if the host job reads past the End Of Data marker and then keeps issuing read commands. The customer should check with their application vendor to understand why this is occurring. This error code may be normal depending on the application. Attachments This solution has no attachment |
||||||||||||||||
|