Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2247935.1
Update Date:2017-05-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  2247935.1 :   T10000A/B/C/D - 376A errors  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek T10000C Tape Drive - Version All Versions and later
StorageTek T10000D Tape Drive - Version All Versions and later
Sun StorageTek T10000 Tape Drive - Version All Versions and later
Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 376A Perm Errors.

Cause

FSC = 376A
(FSC Match Found in Rev. 4.11)

FSC: 376A RO_FSC_FALSE_EOD_EOW_MCF

MIM Code: NONE

FRU: MEDIA CONF: 50%

FRU: HARDWARE CONF: 50%

Summary: |OLD DATA SEEN |ERROR | *** |

Field Text:
While reading, old data was detected that requires error recovery to get over.

Solution

 376A Perm Errors. While reading, old data was detected that requires error recovery to get over. 376A is an informational error code. It indicates that  the job read past the End Of Data marker and is now in old data.

  This is possible if the host job reads past the End Of Data marker and then keeps issuing read commands. The customer should check with their application vendor to understand why this is occurring. This error code may be normal depending on the application.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback