Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2247726.1
Update Date:2017-03-31
Keywords:

Solution Type  Problem Resolution Sure

Solution  2247726.1 :   E5-MCAP Card Analysis  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14542749681>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and later
Information in this document applies to any platform.

Symptoms

Several times the MASP 1113 issued the trouble oamhc_init.c.
Should this card be replaced ?

Cause

This is due to the regular UIM 1120 :

****Logged 17-03-23 03:22:18****
  2830.1120 CARD 1301 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:22:17
  ****Logged 17-03-23 03:25:56****
  3413.1120 CARD 1301 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:25:55
  ****Logged 17-03-23 03:26:27****
  3507.1120 CARD 1301 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:26:27
  ****Logged 17-03-23 03:28:51****
  3903.1120 CARD 1317 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:28:51
  ****Logged 17-03-23 03:29:56****
  4116.1120 CARD 2117 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:29:55
  ****Logged 17-03-23 03:32:05****
  4545.1120 CARD 1317 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:32:04
  ****Logged 17-03-23 03:32:33****
  4641.1120 CARD 2101 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:32:33
  ****Logged 17-03-23 03:40:16****
  1075.1120 CARD 1317 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:40:15
  ****Logged 17-03-23 03:50:14****
  3091.1120 CARD 2201 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:50:13
  ****Logged 17-03-23 03:55:04****
  4005.1120 CARD 1317 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:55:04
  ****Logged 17-03-23 03:55:47****
  4152.1120 CARD 1317 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:55:46
  ****Logged 17-03-23 03:59:57****
  4925.1120 CARD 2101 INFO TRBL Queue is full:elements overwritten
  Report Date:17-03-23 Time:03:59:56
 
According to the source code, this trouble is cause by the UIM 1120
 

Solution

The MASP 1113 does not have to be replaced. The idea is to reduce the UIMs 1120 by making the network more stable.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback