Asset ID: |
1-72-2244634.1 |
Update Date: | 2017-03-21 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2244634.1
:
2 IPSG Cards Were Rebooting With The Obit "ath_vxw.c"
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-14485236811>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.
Symptoms
2 x IPSG cards were unstable, rebooting from time to time with the following obit :
eaglestp 17-03-15 18:37:15 EST EAGLE5 44.0.5-64.34.26
------------------------------------------------------------------------
STH: Received a BOOT APPL-Obituary reply for restart
Card 1111 Module ath_vxw.c Line 2803 Class 0001
Register Dump :
EFL=00000000 CS =0000 EIP=00000000 SS =0000
EAX=00000000 ECX=00000000 EDX=00000000 EBX=00000000
ESP=00000000 EBP=00000000 ESI=00000000 EDI=00000000
DS =0000 ES =0000 FS =0000 GS =0000
Stack Dump :
[SP+1E]=0000 [SP+16]=0000 [SP+0E]=0000 [SP+06]=0000
[SP+1C]=0000 [SP+14]=0000 [SP+0C]=0000 [SP+04]=0000
[SP+1A]=0000 [SP+12]=0000 [SP+0A]=0000 [SP+02]=0000
[SP+18]=0000 [SP+10]=0000 [SP+08]=0000 [SP+00]=0000
User Data Dump :
30 78 30 32 30 30 35 39 37 38 20 41 50 50 4c 20 0x02005978.APPL.
57 61 74 63 68 64 6f 67 20 74 69 6d 65 6f 75 74 Watchdog.timeout
20 72 65 73 65 74 .res
Cause
There was an issue on the ports of the switch which made the cards to reboot as a recovering mean.
Solution
Replace the faulty switch.
Attachments
This solution has no attachment