Solution Type  Problem Resolution Sure

Solution  2243967.1 :   T10000D - 3697 SNO Errors  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Internal only.

Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 3697 SNO Errors on T10000D tape drives.

Cause

FSC Dictionary Description:
MODEL = T10000D
FSC = 3697
(FSC Match Found in Rev. 4.11)

FSC: 3697 RO_FSC_UTIL_SEND_HS_ERR_ACK_OWED

MIM Code: INOPERABLE

FRU: MICROCODE CONF: 100%

Summary: |INVALID UCODE |DATA RECEIVED | *** |

Field Text:
Device Side Task received a command when an acknowledgment was still owed for a previously reported error. This is illegal.

Solution

 Special build RD411113 code has a code change for this SNO problem. The same code change will also be in 4.12.1xx code when it releases.