Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2243913.1
Update Date:2018-03-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2243913.1 :   T10000C - SNO FSC: A004, CO_FSC_PRML1_FPGA_FRAME_CRC_ERROR  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-14473033353>

Applies to:

StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Drive Microcode When the Failure Occurred: 4.11.113
SNO FSC: a004

Bug 25718796

Symptoms

FSC: A004 CO_FSC_PRML1_FPGA_FRAME_CRC_ERROR

Changes

 

Cause

Drive SNO FSC is a004
(FSC Exact Match Found)
FSC: A004 CO_FSC_PRML1_FPGA_FRAME_CRC_ERROR
MIM Code: NONE

FRU: HARDWARE CONF: 100%

Summary: |HARDWARE CRC |ERROR | *** |

Field Text:
Level 13 Interrupt, FRAME CRC Error.

Solution

Replaced tape drive.


Created from <SR 3-14473033353>

Applies to:

StorageTek T10000C Tape Drive
1-914CU


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.