Solution Type  Problem Resolution Sure

Solution  2242377.1 :   "atcp_get_mss: Error Checking For Tunnel Service" appears in acmelog  


Related Items
  • Acme Packet 3820
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-13599413401>

Applies to:

Acme Packet 3820 - Version E-Cz7.3.0 and later
Information in this document applies to any platform.

Symptoms

"atcp_get_mss: Error Checking For Tunnel Service" appears in acmelog  even though there are no tunnels in the deployment.

 

This is not thought to be service affecting.

 

Changes

 none

Cause

 Bug 24504573 - MINOR atcp_get_mss: error checking for tunnel service in ECZ730MR-2 GA.

Solution

 This has been fixed in the ECZ730m2p6 release.

References

<NOTE:1589489.1> - How to Capture all Log Files on Acme Packet systems including 3820,3900,4500, 4600, 6100, 6300
<BUG:24504573> - MINOR ATCP_GET_MSS: ERROR CHECKING FOR TUNNEL SERVICE IN ECZ730MR-2 GA.
<BUG:23270986> - MINOR ATCP_GET_MSS: ERROR CHECKING FOR TUNNEL SERVICE
<BUG:24695502> - MINOR ATCP_GET_MSS: ERROR CHECKING FOR TUNNEL SERVICE
<NOTE:1593644.1> - How to Backup the Session Director Configuration