![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2242377.1 : "atcp_get_mss: Error Checking For Tunnel Service" appears in acmelog
In this Document
Created from <SR 3-13599413401> Applies to:Acme Packet 3820 - Version E-Cz7.3.0 and laterInformation in this document applies to any platform. Symptoms"atcp_get_mss: Error Checking For Tunnel Service" appears in acmelog even though there are no tunnels in the deployment.
This is not thought to be service affecting.
Changesnone CauseBug 24504573 - MINOR atcp_get_mss: error checking for tunnel service in ECZ730MR-2 GA. SolutionThis has been fixed in the ECZ730m2p6 release. References<NOTE:1589489.1> - How to Capture all Log Files on Acme Packet systems including 3820,3900,4500, 4600, 6100, 6300<BUG:24504573> - MINOR ATCP_GET_MSS: ERROR CHECKING FOR TUNNEL SERVICE IN ECZ730MR-2 GA. <BUG:23270986> - MINOR ATCP_GET_MSS: ERROR CHECKING FOR TUNNEL SERVICE <BUG:24695502> - MINOR ATCP_GET_MSS: ERROR CHECKING FOR TUNNEL SERVICE <NOTE:1593644.1> - How to Backup the Session Director Configuration Attachments This solution has no attachment |
||||||||||||||||||||
|