Asset ID: |
1-72-2241579.1 |
Update Date: | 2018-04-10 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2241579.1
:
SL150 - Tape Drive Doesn't Appear To Be Connected To A Host
Related Items |
- StorageTek SL150 Modular Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
In this Document
Created from <SR 3-14017004131>
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Module 5 bottom drive is still having issues. We've had to reseat the module controller multiple times and the drive seems to work a couple of times then needs configuring again.
O,1037,2017-02-14T13:09:21.120,9020,DRIVE_COMM_FAILURE,1,Module 5 Bottom DriveAssembly,2,Module 5 Controller,3,Module 5 Motherboard,,,,,Reseat/replace drive. Reseat/replace controller. Replace motherboard
C,1037,2017-02-14T13:12:33.543,9020,DRIVE_COMM_FAILURE,,,,,,,,,,,Resolved
O,1038,2017-02-14T13:12:43.559,9022,DRIVE_UNSPECIFIED_FAILURE,1,Module 5 Bottom DriveAssembly,2,Module 5 Controller,3,Module 5 Motherboard,,,,,Reseat/replace drive. Reseat/replace controller. Replace motherboard
C,1038,2017-02-14T13:12:53.582,9022,DRIVE_UNSPECIFIED_FAILURE,,,,,,,,,,,Resolved
2017-02-14T11:42:05.272, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T12:27:36.292, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T13:08:00.559, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T13:08:46.717, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T13:09:06.301, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T13:09:18.971, 0.0.0.0.0, 009, VMonitor, , warn, 0000, 6466, "GetDriveStatus: Firing DriveHealthEvent for DriveId 10 Old health state: 2, New health state: 3"
2017-02-14T13:09:36.492, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T13:09:56.073, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
2017-02-14T13:10:15.655, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 10 - Was logged out, had to renegotiate the link!"
Changes
Cause
Module 5 KLE card issue
Solution
Replace Module 5 KLE card
7054651 [C] Expansion Module Controller (KLE) Card
Attachments