SL150 - "1234 CAP Sensor Not Opened After Open Operation" - Bad CAP Sensor on the SL150 Robot
Related Items |
- StorageTek SL150 Modular Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
In this Document
Created from <SR 3-14273053721>
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Tape library having issue with the tape load/remove; Robot is not automatically moving the tapes in/out
Reboot ineffective.
Reporting Error :
2017-02-04T14:14:57.602 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-05T14:02:52.802 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
Changes
Cause
Possible Causes :
-- Obstruction on the robotic path
-- Robot CAP sensor could be faulty
2017-02-04T14:14:57.602 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-05T14:02:52.802 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-05T14:25:05.747 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-05T14:27:43.261 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-05T14:36:27.825 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-08T12:27:33.296 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-08T12:32:10.278 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-08T12:36:02.434 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-09T12:21:46.832 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-09T12:36:38.764 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
2017-02-10T13:43:06.415 error 0.0.0.0.0 1234 "Director - directorVerdeCapResp() directorVerdeCapRequ: CAP sensor not Opened after Open Operation; End of Text" /usr/local/bin/Ifm
Solution
Check if there are any obstructions on the robotic path, if so fix it
Remove the robot assembly and visually inspect for any physical damage / misaligned
Knowledge Doc : sl150 - How to Remove/Replace the Robot CRU in a StorageTek sl150 Modular Tape Library [VCAP](Doc ID 1473774.1)
Re-seat the robot assembly back to the library and check whether the robot initializes / move the tape cartridges.
Replace the robot assembly if issues still persists.