Asset ID: |
1-72-2236874.1 |
Update Date: | 2018-05-17 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2236874.1
:
T10000B - Drive SNO FSC Is 3785
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: informational
Created from <SR 3-14347832792>
Applies to:
Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Tape drive T10000B
Drive Microcode When the Failure Occurred: 1.52.206
SNO FSC: 3785
Cause
Sequence of failure with cartridge TV2310
FSC 38D3
FSC 378F (x2)
FSC 3785 SNO
Log Entry: 1, Volser: TV2310
Log Time: 02/23/2017 20:51:27.796
-----------------------------------------------------------------
Rec/ Sev/MIM Len Servo COT
Event Route (dec) FSC Path Block ID Position Wrap Position
--------------------------------------------------
04-6a 01-05 36 38d3-001a 00000000 00001312 0001 0001d83c
========================================================================
Log Entry: 2, Volser: TV2310
Log Time: 02/23/2017 21:03:19.074
-----------------------------------------------------------------
Rec/ Sev/MIM Len Servo COT
Event Route (dec) FSC Path Block ID Position Wrap Position
--------------------------------------------------
04-62 21-05 276 378f-0000 0003d500 00010d95 0004 0001d83c
Index Event log data (0xf0 bytes):
0: 05010137 378f0000 378f0000 00000000
10: 37f76608 8002e002 81100000 00000003
20: 5d008000 00510e5f 00021e03 00000000
30: 00000000 00002000 0003d5a7 00000000
40: 00020000 0002f563 00003700 02e00283
50: 100500ff 000003fe 02600003 550e5200
60: 021e0300 00000000 00000000 00200000
70: 03d5a900 00000000 02200000 02f56300
80: 003037f7 00000000 00000000 00000000
90: 00000000 00000000 00000000 00000000
a0: 00000000 00000000 00000000 00000000
b0: 00000000 00000000 370002e0 02831005
c0: 00ff0000 03fe0260 0003550e 5200021e
d0: 03000000 00000000 00000020 000003d5
e0: a9000000 00000220 000002f5 63000000
========================================================================
Log Entry: 3, Volser: TV2310
Log Time: 02/23/2017 21:10:57.674
-----------------------------------------------------------------
Rec/ Sev/MIM Len Servo COT
Event Route (dec) FSC Path Block ID Position Wrap Position
--------------------------------------------------
04-62 21-05 276 378f-0000 00057496 000104e6 0006 0001d83c
Index Event log data (0xf0 bytes):
0: 05010137 378f0000 378f0000 00000000
10: 37f56608 8002e002 c1100000 00000003
20: 3b007000 00810578 00021e03 00000000
30: 00000000 00002000 000574f2 00000000
40: 00020000 0002f563 00003700 02e002e3
50: 100500ff 0000030b 02680002 7d056c00
60: 021e0300 00000000 00000000 00200000
70: 0574f400 00000000 03a00000 02f56300
80: 003037f5 00000000 00000000 00000000
90: 00000000 00000000 00000000 00000000
a0: 00000000 00000000 00000000 00000000
b0: 00000000 00000000 370002e0 02e31005
c0: 00ff0000 030b0268 00027d05 6c00021e
d0: 03000000 00000000 00000020 00000574
e0: f4000000 000003a0 000002f5 63000000
========================================================================
Log Entry: 4, Volser: TV2310
Log Time: 02/23/2017 21:18:52.036
-----------------------------------------------------------------
Rec/ Sev/MIM Len Servo COT
Event Route (dec) FSC Path Block ID Position Wrap Position
--------------------------------------------------
04-da 51-05 36 3785-0000 00000000 0001100d 0008 0001d83c
FSC Dictionary Description:
MODEL = T10000B
FSC = 378F
(FSC Match Found in Rev. 1.52)
FSC: 378F RO_FSC_READ_HDWR_NOT_MAKING_PROGRESS_NO_MCF
MIM Code: NONE
FRU: MEDIA CONF: 80%
FRU: HARDWARE CONF: 20%
Summary: |MEDIA ERROR |*** | *** |
Field Text:
The read code was not making any progress while reading from tape.
Support Annotations:
rob.wilber@oracle.com on 2014-12-05 14:58:28 wrote:
T10000A/T10000B - FSC 378F - Please see if the same tape is failing to read on multiple drives. If it is then this tape may need to be sent in for Data Recovery. Please contact the data recovery personnel.
FSC Dictionary Description:
MODEL = T10000B
FSC = 3785
(FSC Match Found in Rev. 1.52)
FSC: 3785 RO_FSC_NO_MCF_ON_END_WRAP_OP_COMP
MIM Code: NONE
FRU: HARDWARE CONF: 100%
Summary: |NO MCF AT END OF| WRAP | *** |
Field Text:
No valid data matrix data reported at the end of the current wrap.
Solution
If cartridge TV2310 can be read on different drive(s), than suggest to replace this drive.
Drive DMOD Serial Number: 572004005922
Please see if the same tape (TV2310) is failing to read on multiple drives.
If it is, then this tape may need to be sent in for Data Recovery if customer requires data from this cartridge which he can not access from anywhere else!!!
Attachments
This solution has no attachment