Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2232547.1
Update Date:2017-02-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2232547.1 :   LSMS GUI Showing "Local Services Manager connection failed" bouncing for EMS Status  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14247136731>

Applies to:

Oracle Communications EAGLE (Hardware) - Version ELAP 10.1 and later
Tekelec

Symptoms

LSMS GUI Showing "Local Services Manager connection failed"  bouncing for EMS Status from Red to Green

Cause

In this case it appears the supman process was having issues.

Solution

Restart the supman process


Attachments