Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2232146.1
Update Date:2017-03-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  2232146.1 :   Post ODA Reimage To 12.1.2.9.0 components showed not as 'Up-to-date"  


Related Items
  • Oracle Database Appliance X4-2
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  


Post ODA Reimage To 12.1.2.9.0 components showed not as 'Up-to-date"

In this Document
Symptoms
Changes
Cause
Solution
  


Created from <SR 3-14203514291>

Applies to:

Oracle Database Appliance X4-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After re-imaged X4-2 ODA to 2.1.2.9.0 using the 2 zip files p12978712_121290_Linux-x86-64_[1|2]of2.zip, the output of command "oakcli show version -detail" shows some components are not up-to-date.

Component Installed Supported
Name Version Version
SSD_SHARED A122 A29A
HDD_LOCAL A690 A72A
HDD_SHARED A690 A72A
ILOM 3.2.4.20.a r94217 3.2.7.32.a r112581
BIOS 25020500 25030100

there is no issue during the re-image

System Version Component Name Installed Version Supported Version
-------------- --------------- ------------------ -----------------
12.1.2.9.0
Controller_INT 11.05.03.00 Up-to-date
Controller_EXT 11.05.03.00 Up-to-date
Expander 0018 Up-to-date
SSD_SHARED A122 A29A
HDD_LOCAL A690 A72A
HDD_SHARED A690 A72A
ILOM 3.2.4.20.a r94217 3.2.7.32.a r112581
BIOS 25020500 25030100
IPMI 1.8.12.4 Up-to-date
HMP 2.3.5.2.5 Up-to-date
OAK 12.1.2.9.0 Up-to-date
OL 6.8 Up-to-date
GI_HOME 12.1.0.2.161018(2400 Up-to-date
6101,23854735)
DB_HOME 12.1.0.2.161018(2400 Up-to-date
6101,23854735)

 

Changes

 upgrade to 12.1.2.9.0

Cause

This is expected after a re-image as re-image do not touch firmware

Solution

 download the upgrade package to run upgrade -server.Please download the Patch 25064836 and follow README

oakcli update -patch --server -local (on both nodes)
oakcli update -patch --storage

Reimage will not touch ilom bios firmware, above package is used to upgrade them.

 

  

 

 

 