![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2232146.1 : Post ODA Reimage To 12.1.2.9.0 components showed not as 'Up-to-date"
Post ODA Reimage To 12.1.2.9.0 components showed not as 'Up-to-date" In this Document
Created from <SR 3-14203514291> Applies to:Oracle Database Appliance X4-2 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsAfter re-imaged X4-2 ODA to 2.1.2.9.0 using the 2 zip files p12978712_121290_Linux-x86-64_[1|2]of2.zip, the output of command "oakcli show version -detail" shows some components are not up-to-date. Component Installed Supported
Name Version Version SSD_SHARED A122 A29A HDD_LOCAL A690 A72A HDD_SHARED A690 A72A ILOM 3.2.4.20.a r94217 3.2.7.32.a r112581 BIOS 25020500 25030100 there is no issue during the re-image System Version Component Name Installed Version Supported Version
-------------- --------------- ------------------ ----------------- 12.1.2.9.0 Controller_INT 11.05.03.00 Up-to-date Controller_EXT 11.05.03.00 Up-to-date Expander 0018 Up-to-date SSD_SHARED A122 A29A HDD_LOCAL A690 A72A HDD_SHARED A690 A72A ILOM 3.2.4.20.a r94217 3.2.7.32.a r112581 BIOS 25020500 25030100 IPMI 1.8.12.4 Up-to-date HMP 2.3.5.2.5 Up-to-date OAK 12.1.2.9.0 Up-to-date OL 6.8 Up-to-date GI_HOME 12.1.0.2.161018(2400 Up-to-date 6101,23854735) DB_HOME 12.1.0.2.161018(2400 Up-to-date 6101,23854735)
Changesupgrade to 12.1.2.9.0 CauseThis is expected after a re-image as re-image do not touch firmware Solutiondownload the upgrade package to run upgrade -server.Please download the Patch 25064836 and follow README oakcli update -patch --server -local (on both nodes)
oakcli update -patch --storage Reimage will not touch ilom bios firmware, above package is used to upgrade them.