| Asset ID: |
1-72-2231586.1 |
| Update Date: | 2018-03-01 |
| Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2231586.1
:
T10000A - Drive Has Stuck Tape, FSC FE01
| Related Items |
- Sun StorageTek T10000A Tape Drive
|
| Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidentual for service personnel
Created from <SR 3-14169067599>
Applies to:
Sun StorageTek T10000A Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Version: 1.50.103-5.30
Symptoms
FSC FE01
Stuck tape on drive
Tried power off and on but tape will not unload.
Changes
Cause
2017-01-31 17:16:00 FSC Encountered: fe01 Volser:
(FSC Exact Match Found)
FSC: FE01 ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED
MIM Code: INOPERABLE
FRU: HARDWARE CONF: 95%
FRU: MICROCODE CONF: 5%
Summary: |WAKEUP DIAG |FAILED |REGISTER VALUE |
Field Text:
The DC hardware compression wakeup diagnostic failed.
Solution
Support Annotations:
T10000a/B - if the drive was recently power cycled and took this error coming up then the drive needs to be replaced. There is a defective chip in the drive. No failure analysis (FA) is necessary on the drive.
Replace the tape drive.
Created from <SR 3-14169067599>
Applies to:
Sun StorageTek T10000A Tape Drive
1-914CU
Attachments
This solution has no attachment