Solution Type  Problem Resolution Sure

Solution  2231586.1 :   T10000A - Drive Has Stuck Tape, FSC FE01  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidentual for service personnel
Created from <SR 3-14169067599>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Version: 1.50.103-5.30

Symptoms

FSC FE01

Stuck tape on drive
Tried power off and on but tape will not unload.

Changes

 

Cause

 2017-01-31 17:16:00 FSC Encountered: fe01 Volser:
(FSC Exact Match Found)
FSC: FE01 ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED
MIM Code: INOPERABLE
FRU: HARDWARE CONF: 95%
FRU: MICROCODE CONF: 5%
Summary: |WAKEUP DIAG |FAILED |REGISTER VALUE |
Field Text:
The DC hardware compression wakeup diagnostic failed.

Solution

Support Annotations:
T10000a/B - if the drive was recently power cycled and took this error coming up then the drive needs to be replaced. There is a defective chip in the drive. No failure analysis (FA) is necessary on the drive.

Replace the tape drive.