Asset ID: |
1-72-2228189.1 |
Update Date: | 2018-03-02 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2228189.1
:
SL150 - Warning Messages 3345 - Drive reported empty after put! Loading anyway
Related Items |
- StorageTek SL150 Modular Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
In this Document
Created from <SR 3-14012645874>
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Several messages 3345 on both drives of Expansion Modulo 2.
> 2017-01-13T19:09:23.064 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Bottom Drive reported empty after put! Loading anyway."
> 2017-01-14T01:54:36.254 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-14T21:02:17.050 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-14T21:31:15.882 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Bottom Drive reported empty after put! Loading anyway."
> 2017-01-15T01:38:45.815 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-15T07:52:53.462 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-15T16:02:52.164 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-16T03:47:24.080 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-16T07:46:17.829 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-16T11:42:15.228 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
Changes
Upgrade of the two Expansion Module and more 3 x HP LTO6 HH FC.
Cause
The problem was caused after installation of more two Expansion Module.
Solution
Replaced the Expansion Module.
References
<BUG:15784978> - SUNBT7160718 LOG WARNING: "DRIVE REPORTED EMPTY AFTER PUT! LOADING ANYWAY" MESSA
Attachments