Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2228189.1
Update Date:2018-03-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  2228189.1 :   SL150 - Warning Messages 3345 - Drive reported empty after put! Loading anyway  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-14012645874>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Several messages 3345 on both drives of Expansion Modulo 2.

> 2017-01-13T19:09:23.064 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Bottom Drive reported empty after put! Loading anyway."
> 2017-01-14T01:54:36.254 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-14T21:02:17.050 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-14T21:31:15.882 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Bottom Drive reported empty after put! Loading anyway."
> 2017-01-15T01:38:45.815 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-15T07:52:53.462 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-15T16:02:52.164 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-16T03:47:24.080 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-16T07:46:17.829 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."
> 2017-01-16T11:42:15.228 warn 0.0.0.0.0 3345 "IfmMove::commonMoveCommand():Drive: (P:MR) 0:2,Top Drive reported empty after put! Loading anyway."

Changes

 Upgrade of the two Expansion Module and more 3 x HP LTO6 HH FC.

Cause

The problem was caused after installation of more two Expansion Module.

Solution

Replaced the Expansion Module.

References

<BUG:15784978> - SUNBT7160718 LOG WARNING: "DRIVE REPORTED EMPTY AFTER PUT! LOADING ANYWAY" MESSA

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback